YJ-MT 100L 200L Vacuum Steam Autoclave

Pressure steam atuoclave sterilizer: An automatic high temperature and pressure sterilizer with pressure steam as medium. For the sterilization of medical devices, laboratory utensils, media and materials that may come into contact with blood or body fluids by unsealed liquids or preparations. Applicable to stomatology, ophthalmology, operating room, supply room and other medical and health departments for all packaged or unpackaged: solid road device, class A cavity device (dental mobile phone, endoscope), implanted device.

Product Feature

1.The touch screen display of temperature, pressure,time,running status and failure warning.

2.Pre-set cycles for a variety of items and tests, alarms, safety systems, temperature working range, vacuum diagnostic system, Bowie Dick Type Test.

3.Custom mode :possible for operator to alter parameters/add new operating cycles.

4.3-times pre-vacuum, effective discharge cold air from chamber to improve steam efficiency.

5.Internal steam generator, PLC control, space and energy saving.

6.Equipped with post-drying function which makes the residual humidity of sterilized articles less than 0.2%.

7.Water shortage alarm, Over-heat auto protection device, door safety lock device, over-pressure relief valve, short-circuit protection and over-pressure protection.

8.Perfect program design system to avoid damage caused by mistake operation.

9.The post-sterilization hot steam is cooled down before discharge from machine.

10.Equipped with water quality monitor . extend the machine service life.

 

 

Technical Specification

Equipment Type

vacuum steam autoclave sterilizer

Certificate

CE ISO CFDA

Machine size

1150*770*1520 mm(100L)

1360*810*1580(200L)

Working temperature

121 -134 

Power supply

AC 380V, 50Hz

Working pressures

210kPa-230kPa (2.1-2.3Bar)

Space needed

the machine shell are removable, end wheels , 500 mm space from 

Autoclave are enough for maintenance

Safety over-pressure

1.Over-pressure   warning alarm

2. safe pressure relief valve

3. over-temperature   heating shut-off device

Safety door interlock

PLC set: the door can't open while vessel is under pressure;   

can't start up if the door is not properly closed

Safety emergency shut-off

Red Emergency button in a readily accessible location

Safety   surfaces

Surfaces operator may contact NOT exceeding 50°C

Safety vacuum breaker

During a power outage or other failure the vacuum will stop,

and replace to the Atmosphere

Materials of construction

304 stainless steel

Pre-set operating cycles

Pre-set modes: naked instrumentfabric  rubber   ,high pressure

Pre-set   leak testing

Pre-set   BD test(Bowie Dick Type Test) for leak testing and 

vacuum pump diagnose.

Door

mechanical rotating locking   with electronic sensor

Controls

1. multiple pre-set operating cycles.

2. user setup ,possible for operator to alter pre-set cycle parameters/add 

new pre-set operating cycles

3. system setup ,For purposes of maintenance, testing, or in cases of emergency.

4. The sterilizer protected against the effects of short circuit in inputs and outputs that 

are connected to the controller

Display indicators

door locked, operation in progress, major operating cycle stages, and cycle complete ,times ,

temperature ,pressure , fault condition readable by normal  vision from a distance of 1.2 m

Indicator for temperature

± 1%   accuracy over the scale range 50°C to 150°C;

0.1°C   resolution for digital display

Indicator for pressure

± 1.6% over the scale range -0.6 bar to 3 bar; 0.1kpa (0.001bar) resolution for digital display

Indicators for processing time

Error not to exceed 1%

Fault condition

In the event of a failure of the automatic controls, or if a failure occurs that prevents the

completion of the process, the controls screen   show a visual indication of failure and an audible alarm.

Mini printer Recording

Recording of time, temperature and pressure   include values during transition points 

throughout the operating cycle

Vacuum

-80Kpa ~90Kpa ( -0.8bar ~0.9 bar )

Decontamination of air

Air filter with activated carbon filtration, steam treatment to prevent release of pathogenic aerosols

Markings

Markings for safety and operation   comply with EN 13445

Manuals

English language.

1. Operation instructions (including process description),

2. Loading and maintenance procedures.

3. Short-form of operation and loading procedures.

Spare parts(option)

a. Heating element

b. Door seal/gasket

c. Replacement air filter

d. Safety valve

e. Pressure and temperature gauges