Adopt European Class B standard, suitable for all kinds of packaging, unpacked, solid and internal plumbing machinery. Built-in independent steam generator. Sterilization, drying time can be manually adjusted, so that sterilization, drying effect to achieve the best working state.
1. The third vacuum and the first vacuum are integrated into one, which is convenient for the user to disinfect different items.
2. Built-in two vacuum pumps for faster sterilization time.
3. Built-in independent steam generator.
4. The sterilization time and drying time can be adjusted freely.
5. Newly added separation and drying procedure (optional).
6. Dual gate protection locking system is superior.
7. Oversized liquid crystal display to make the state of the data displayed more intuitive.
8. Built-in printers make it easy to print sterilized records (optional).
9. Built-in USB interface, flexible choice of sterilization data recording and storage mode.
Sterilization roon size(cm) |
Φ31.9*61.5 |
Outline dimension(cm) |
94*59*57.5 |
Product form |
Desktop |
Heating mode |
electrical heating |
Power supply |
AC220V,50Hz |
Sterilizing chamber material |
The sterilizing chamber is 304 anticorrosive stainless steel with thickness ≥ 3mm, safety door thickness ≥ 15mm, hydraulic test ≥ 0.8mpa. which exceeds the national standard of YY0646-2008 design. |
Outer box material |
Carbon steel (1.5mm thick) baking powder |
Work environment |
0-50ºC |
Working pressure |
-80kpa~200kpa |
Sterilization humidity |
≥80% |
Maximum pressure resistance |
-120kpa~260kpa |
Sterilization temperature |
121ºC-135ºC adjustable |
Vacuum mode |
Three pre-vacuum to ensure faster heating, sterilization more thorough. |
Over voltage protection program |
When the sterilizing chamber pressure reaches 220 ±5kPakPa, there are cues and automatic pressure relief. |
Pressure sensor |
The inner pressure sensor automatically detects the pressure inside the cavity to ensure the accuracy and efficiency of the pressure. |
Temperature sensor |
The built-in temperature sensor automatically detects the temperature inside the cavity to ensure that the temperature in the cavity is within the accurate range of ±3 ºC. |
Sterilization mode |
Bare equipment, cotton yarn, wrapping equipment, plastic and rubber equipment products, the default working temperature is 135 ºC. |
Sterilization time at 135 ºC |
36 minutes(Preheat 12 minutes, vacuum 4 minutes, sterilization 4 minutes, dry 16 minutes) |
Sterilization time at 122 ºC |
56 minutes(Preheat 8 minutes, vacuum 4 minutes, sterilize 5-20 minutes, dry 20 minutes) |
Alarm system |
High and low temperature alarm system |