If you have any question, please contact us
Product name : Flow cytometry analyzer
Model: YJ-Cyte1024
Application: hospital and research institute
Laser : double
Color: 4
Channel: 6
hardware:
New photoelectron detector application, high sensitivity, after extremely linear optimization, up to 10 of 6
Power real dynamic detection range, excellent indicators.
Spatial three-dimensional separate excitation, spatial three-dimensional separate reception, no crosstalk between different laser channels, no compensation;
Fixed optical path design, simplest degree of freedom adjustment, simple locking method, high precision, high stability after maintaining vibration
New solid-state laser, new integrated heat sink integration process, minimize laser spot drift, heat engine time<4 Minutes, ready to use
Absolute counting function, including microsphere counting, and an upgradeable volume counting function
Automatic hydraulic circuit maintenance function, automatic hydraulic circuit maintenance reminder, simplify daily maintenance work
Upgradeable tray autosampler solution
software:
Threshold, voltage and compensation can be set in debug mode first, and then data can be collected
Support the pause/continue function during the acquisition process, and support large-volume continuous sample testing
Data and setting parameters can be automatically saved in the background, and can be recalled at any time in an automatic save mode against power failure
Parameter |
System Index |
Laser |
Double laser (488nm, 638nm) 6 colors |
Optical filter |
Double laser (488nm, 638nm) 6 colors
488nm laser: 538nmBP FITC, 585nmBP PE,700nmBP PerCP-Cy5.5/PE-Cy5,785nmBP PE-Cy7 638nm laser: 660nmBP APC, 785nmBP APC-Cy7 |
Fluorescence |
FITC<35 MESF |
FSC Resolution |
0.5μm |
SSC Resolution |
0.2μm |
Measurement |
>6 logs |
Fluorescence Precision |
CV≤2% |
Detection range |
0-5000pg/ml |
Data Acquisition Rate |
45,000 events/second, Maximum |
Counting Function |
Yes |
Start Time |
<4minutes |
Custom Core Diameter |
0.2-50μm |
Minimum Sample Volume |
<20μL |
Custom Sample Flow Rates |
15 ~ 235μL/Min |
Recommended sheath fluid |
Deionized water/ Ultra-pure water |
Bucket capacity |
Waste liquid bucket 6L |
Automatic cleaning system |
A variety of liquid system automatic maintenance procedures, one button automatic operation |
Cross contamination rate |
≤0.1% |
Instrument Dimension |
Host 44x43x52cm (LxWxH) |
Net Weight |
Host 32kg |
Packing Details |
Wooden Carton Size:100x63x95cm |
Operation Environment |
Temperature: 10 - 35°C |
Power Supply |
98-264VAC |
Computer |
Dell+23screen |
Software |
Compatible with FCS2.0 and 3.0/3.1 industry standard data format; Support export.CSV and .TXT formats |
If you have any question, please contact us