If you have any question, please contact us
Technical Specificaions:
Assay Model: Random access with direct reading system
Assay Item: 40 assay
Throughput: 1Reagent:300 test/h(max); 2 Reagent: 240 test/h;
Light Source: Halogen lamp
Method: End point, Kinetic, Fixed time, Immunoturbidimetry, 1-2 reagen,Multistandard,reagent/serum blank, etc
Quality Control: Levy Jennings quality control program at 3 levels.
Printer: Multiple report formats available
Assay Model: Random access with direct reading system
Assay Item: 40 assay
Throughput: 1Reagent:300 test/h(max); 2 Reagent: 240 test/h;With ISE: +120 test/h
Sample Position: 60
Sample Volume: 1-100ul,0.1ul/step
Reagent Position:40 or 80(optional)
Reagent Volume: R1:1-400ul,1ul/step,R2: 1-400ul,1ul/step
Wavetength: 340-810nm
Light Source: Halogen lamp
Method: End point, Kinetic, Fixed time, Immunoturbidimetry, 1-2 reagen,Multistandard, reagent/serum blank, etc
Quality Control: Levy Jennings quality control program at 3 levels.
Printer: Multiple report formats available
Model |
YJ-300 |
Assay type |
Random access system |
Throughput |
1 Reagent: 300 tests/h(max) |
2 Reagent: 240 tests/h(max) |
|
|
With ISE: +120 tests/h |
Sample capacity |
2X100 primary tube or micro serum cup |
Sample Position |
80, Including standard, control and stat; either serum cup or primary tube available |
Sample/ reagent probe |
With liquid level sensor, auto checking and tracking reagent allowance ability, internal and external nano treated, collision protection, plugging probe checking ability |
Sample volume |
1.0 – 100ul in 0.1ul/step |
Reagent volume |
1.0 -400ul in 0.1ul/step |
Reagent refrigerator |
2 – 8℃, 24 hours available |
Reagent tray |
2 reagents trays, barcode scanner available (on request) |
Reading cuvette |
160 UV plastic cuvettes ( quartz glass cuvette available) |
Reaction volume |
Minimum 120 ul |
Reaction disc temp. |
Water bath system, 37±0.1℃ |
Cuvette cleaning |
Automatic warm water washing station with 8 channels |
Carry-over |
Less than 0.1% |
Monochromator |
Optical grating |
Wavelength range |
12 channels, 340nm, 405nm, 450 nm, 480 nm, 505 nm, 546 nm, 570 nm, 600 nm, 660 nm, 700 nm, 750 nm, 800 nm |
Alarm |
Automatic alarm for lack of reagent, sample, water or waste filled and other error, show the info. On monitor |
Mixer |
2 nao-surface treated mixer probers, with automatic warm water wash station |
Quality control |
Multi- level QC for the same item automatically monitoring and alarming if the results out of control |
Assay linearity range |
Wide linearity range measuring, also with automatically diluting function for high value sample |
Calibration |
Single or multi-points calibration, supporting linear and nonlinear assay |
Data processing |
Powerful software for calculating, blanking, multi-analysis, data reviewing, QC and results management, on-line monitoring, editing, etc. |
Data storage |
Long-term storage, storage capacity upon PC hard disc |
|
Multi report formats and user-self-defined report format available |
Power supply |
110V / 60Hz or 220V / 50Hz(optional) |
Dimensions Weight |
1050X880X1170(mm) |
If you have any question, please contact us