If you have any question, please contact us
Product name: flow cytometry analyzer
Warranty: 1 year
laser configuration: Up to 3 lasers 405nm (100mW),488nm (60mW) ,638nm (80mW)
Configuration upgrade
Up to 3 lasers and 15 fluorescent channels are configured.with a maximum of 18 detection parameters
Powerful function
High resolution, high sensitivity and high stability
Automatic
Full-automatic detection process, synchronous collection/analysis
Quick loading
Up to 50000 events/s injection speed, greatly improving injection efficiency
Injection options
The automatic sampler supports 40 tubes auto sampler/96holes plate, which is simple and efficient
New elliptical spotlaser
The external beam shaping of the laser is extremely simple. The polychromaticlaser beam shares a focus lens, and the optical path is stable and reliable.
New WDM beam splitter module
Only one dichroic filter is used in each WDM, and the subsequent spectralseparation is based on the transmission characteristics of the band-pass filterinside the band and the reflection characteristics of the band-pass filter outsidethe band, which not only reduces thenumber offilters used, but also reducesthe energy loss, and further improvesthe fluorescence detection sensitivity.
Plunger pump sample injection system
Precise sample injection ensures theaccuracy of absolute counting by volume method
New automatic sampler with mixing function
40-tube Rotary/96-well microplate
High efficiency
40-tube Rotary can be tested within 30mins96-well microplate can be tested within 40mins
Injection probe with rinsing swab
The inner and outer walls of the injection probe canbe cleaned at the same time, effectively reducingthe probability of needle pluggingAutomatic cleaning between experiments caneffectively reduce the cross contamination rate<0.1%
Oncology and Hematology | Analysis of 6-color human peripheral bloodimmune cell subsets Analysis of 9-color human peripheral bloodimmune cell subsets Detection of dendritic cells (DC) Phenotypic characterization of natural killercell(NK) populations Characterization of PBMC T cell receptors Detection of CD62P Platelet Activation |
Immunology | Detection of T cell proliferation(CFSE) Detection of B-cell antibody class Nk cell-mediated clearance of spleen cells Detection of Treg cell subsets |
Stem cells | Flow cytometry analysis of hematopoieticstem cells from mouse bone marrow Detection of CAR-T extracellular tumor killing Analysis of mesenchymal stem cells frombone marrow and endometrium of miceFlow cytometry analysis of mousehematopoietic progenitor cells |
Name | Main parameter indicators |
Laser configuration | Up to 3 lasers 405nm(100mW),488nm(60mW),638nm(80mw) |
Instrument resolution | <2% |
Fluorescence detectian limit | FITC< 50MESF;PE< 30MESF;APC< 30MESF |
Fluorescence linearity | 2-0.99 |
Detector | APD Detector |
Forward scatlered light resolufon | <0.45μm |
Detection particle range | 0.2-50μm |
Carryover rate | <0.1% |
Absolute count | Compatible with volumetric and microsphere absolute counting |
Detecticn speed | >50000 events/s |
Signal range | Maximum10 |
Injection speed | Low: 15μL/min: Medium: 30μL/min; High 1: 60μ L/min;High 2:90u L/min; High 3:120μL/min Adjustable speed range:15-120 μ L/min |
Threshold setting | Supports dual thresholds to minimize cell debris |
Fucresoence compensabion | Suocort automatic online compensation, offine compensation and visual compensation tools |
Project template | Support project template function, one-click calling of acquisition conditiorisMiuoresceince compensation information |
Instrument quality contro | Automatic daily QC inspection, tracking and recording through Levery-Jennings |
lnjection mode | Single tube manual sampling |
40 tubes auto sampler with single sample mixing function | |
96-hole plates | |
Software | English interface, support acquisition and analysis at the same time |
File format | Support FCS3.1/FCS3.0 and FCS2.0 format files |
Mainterance method | Startup initialization,startup cleaning, cleaning between experiments, shutcwn cleaning.exhaust bubble.etc |
Aulomatic maintenance procedure for monthly cleaning (deep cleaning) | |
Computer configuration | DELL/CPU 15/Memory 8G/HDD 1T/27 inch monitor |
Size and weight | 760mm*450mm*470mm(length"widththeight),40KG |
If you have any question, please contact us