If you have any question, please contact us
YJ-8501 Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient’s respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.
YJ-8501 Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient’s respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.
Pneumatically driven and electrically controlled system
Built-in ventilator, 8.4” LCD display screen
Closed; Semi-Closed; Semi-Open working mode
Applied for Adult and Pediatric
Pneumatically driven and electrically controlled system
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa.
Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,VCV,PCV,PEEP,SIGH,MANUAL
Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea,AC power malfunction,Battery low power.
Operating Modes: Pneumatically driven & electronically controlled, closed, semi-closed and semi-open
Anesthesia Ventilator: Built-in ventilator, 8.4" LCD display screen
Standard integrated metallic modular respiratory circuit; completely solves the problem of gas sealing under high temperature disinfection, easy to clean and disinfect
Equipped with electronic pressure differential flow sensor, imported respiratory control valve
Vaporizer: Imported tank components assembled locally; Enflurane, Isoflurane, and Sevoflurane (Halothane optional). Also possesses self-compensating functionality
Multi-parameter Patient Monitor: Optional
High precision five- tube flowmeter, fitted with interlocking oxygen-nitrous oxide supply, guarantees oxygen output is never lower than 21%
Nonhazardous environmentally-friendly frame, with automated self-checking function during startup and an automatic self-calibrating sensor
Power Failure Support Functions: Automatically converts to backup power mode during AC power outages
Alarms: Audible and/or visual alarms for tidal volume, airway pressure, asphyxia, power failure, oxygen failure and other alarms, also features a alarm query function
Equipped with an advanced international rotating Na-lime tank, uses imported PPSU material and temperature resistant to 134°C
Parameters | |
Built-in ventilator | YES |
Display screen | 8.4” LCD display screen |
Working mode | Closed; Semi-Closed; Semi |
Application | Adult and Pediatric |
5-tubes Flowmeters | O2 & N2O & Air ; 0.1L/Min ~ 10L / Min |
Oxygen Flush | 25~75 L / Min |
Tidal Volume | Adjustable range:20 ~ 1500 ml, |
Display range:0~2000ml | |
I/E Ratio | 8:1 ~ 1:10 |
Two vaporizers | Enflurane/ Isoflurane/Sevoflurane/Halothane |
Vaporizer Setting Range | 0.5%~5% |
Respiration Frequency | 1~100 bpm |
Lung compliance | ≤30 mL / kPa |
IMV frequency | 1~20 bpm |
PEEP | 0 ~ 2.0 kPa |
Ptr | -1.0kPa ~ 2.0 kPa |
CO2 absorber capacity | 1KG |
Inspiratory Plateau | 0~1 S |
O2 Concentration | 21%~100% |
Patient monitor | Optional |
We are professional Supplier of Anesthesia Machine Patient Monitor in China,wish we can provide you solution on operations.
If you have any question, please contact us