Comparison of various anesthesia machines

 

Model No. YJ-801 YJ-802 YJ-PA01 YJ-PA02 YJ-8501 YJ-8502
PIC
Screen N N 5.4”LCD display screen 5.4”LCD display screen 8.4”LCD display screen 10.4”LCD display screen
PEEP N N N N 0 ~ 2.0 kPa 0 ~ 2.0 kPa
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa.
Flow meters: 2-tubes O2 & N2O; 0.1L/Min ~ 10L / Min; 2-tubes O2 & N2O; 0.1L/Min ~ 10L / Min; 4-tubes O2 & N2O; 0.1L/Min ~ 10L / Min; 4-tubes O2 & N2O; 0.1L/Min ~ 10L / Min; 5-tubes O2 & N2O; 0.1L/Min ~ 10L / Min; 5-tubes O2 & N2O; 0.1L/Min ~ 10L / Min;
Oxygen Flush 25~75 L / Min 25~75 L / Min 25~75 L / Min 25~75 L / Min 25~75 L / Min 25~75 L / Min
Respiration Mode: A/C, IPPV, SIPPV, MANUAL A/C, IPPV, SIPPV, MANUAL A/C, IPPV, SIPPV, IMV, SIMV, MANUAL A/C, IPPV, SIPPV, IMV, SIMV, MANUAL A/C, IPPV, SIPPV, IMV, SIMV, VCV, PCV, PEEP, SIGH, MANUAL A/C, IPPV, SIPPV, IMV, SIMV, VCV, PCV, PEEP, SIGH, MANUAL
Tidal Volume: 50~1500ml 50~1500ml 0~1500m 0~1500m Adjustable range:20 ~ 1500 ml,
Display range:0~2000ml
Adjustable range:20 ~ 1500 ml,
Display range:0~2000ml
I/E Ratio: 1:1.5 ~ 1:3.0 1:1.5 ~ 1:3.0 4:1 ~ 1:10 4:1 ~ 1:10 8:1 ~ 1:10 8:1 ~ 1:10
vaporizers: 1 2 1 2 2 2
Vaporizer Setting Range: 0.5%~5% 0.5%~5% 0.5%~5% 0.5%~5% 0.5%~5% 0.5%~5%
Respiration Frequency: 4~40 bpm 4~40 bpm 1~99 bpm 1~99 bpm 1~100 bpm 1~100 bpm
Ptr: -1.0kPa ~ 1.0 kPa -1.0kPa ~ 1.0 kPa -1.0kPa ~ 1.0 kPa -1.0kPa ~ 1.0 kPa -1.0kPa ~ 2.0 kPa -1.0kPa ~ 2.0 kPa
CO2 absorber capacity: 1 kg 1 kg 1 kg 1 kg 1 kg 1 kg
Built-in ventilator N Y Y Y Y Y
Alarm parameters upper/lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, Battery low power. upper/lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, Battery low power. upper/lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, Battery low power. upper/lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, Battery low power. upper/lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, Battery low power. upper/lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, Battery low power.
Way of volume control pneumatic transmission system Pneumatically driven and electrically controlled system Pneumatically driven and electrically controlled system Pneumatically driven and electrically controlled system Pneumatically driven and electrically controlled system Pneumatically driven and electrically controlled system
Optional Patient monitor Y Y Y Y Y Y